In high-cleanliness environments such as semiconductor manufacturing, biopharmaceuticals, and aerospace, cleanroom wipes are critical consumables for maintaining cleanroom classification and process stability. The IEST (Institute of Environmental Sciences and Technology) released the IEST-RP-CC004.4 standard, providing a scientific and systematic testing framework for quality control of cleanroom wipes. This article analyzes the key test items and their purposes based on the standard, revealing its technical value in cleanroom applications.

1. Particle Release Characterization

  • Liquid Particle Counting (LPC, 0.5–20 μm):
    Using a liquid particle counter combined with orbital shaking to simulate mechanical friction on wet wipes, quantifying released particles between 0.5 and 20 microns to prevent contamination of precision instruments and interference with optical surfaces.

  • Fiber Analysis (>100 μm):
    Optical microscopy is used to detect large residual fibers or particles after orbital shaking, preventing clogging of microporous structures or mechanical failures caused by macroscopic particles.

  • Airborne Particle Counting (APC, 0.3–10 μm):
    Helmke drum simulates dry state wipe motion, and airborne particle counters monitor particle release between 0.3 and 10 microns to assess particulate risk during dynamic cleanroom operations.

2. Chemical Contaminant Analysis

  • Ion Content Test (IC):
    After extraction with deionized water, ion chromatography detects anions (F⁻, Cl⁻, NO₃⁻, etc.) and cations (Na⁺, K⁺, Ca²⁺, etc.) to prevent ion residues from corroding electronic components or interfering with chemical processes, especially crucial in semiconductor wafer manufacturing.

  • Non-Volatile Residue (NVR) Test:
    Short-term extraction with deionized water and isopropanol followed by evaporation and weighing quantifies transferable oils and polymers, preventing deposition on sensitive surfaces.

  • Fourier Transform Infrared Spectroscopy (FTIR):
    After hexane extraction, FTIR detects organic compounds such as silicone oils, amides, and phthalates (DOP), identifying potential contamination sources to protect optical components and ensure biocompatibility.

3. Physical Performance and Functional Evaluation

  • Liquid Absorption Capacity and Rate:
    Measures maximum liquid uptake per unit area and absorption speed, ensuring wiping efficiency and avoiding contamination from insufficient liquid absorption leading to repeated wiping.

  • Surface Static Charge Test:
    Measures surface resistivity to control static accumulation risk and prevent electrostatic discharge (ESD) damage to electronic components.

4. Biological Contamination Control

  • Bioburden Test:
    Microbial culture methods quantify aerobic bacteria and fungi counts on wipe surfaces, ensuring wipes do not introduce microbial contamination in pharmaceutical or biological lab environments.

5. Technical Significance of the Standard
IEST-RP-CC004.4 comprehensively covers physical, chemical, and biological performance indicators of cleanroom wipes through multi-dimensional testing. It offers graded particle control from submicron to macroscopic fibers, compatible with ISO Class 1 to 5 cleanrooms, tightly controls ions and organic contaminants for semiconductor and optical industries, and verifies absorption efficiency and antistatic performance to guarantee operational reliability. This standard provides a scientific basis for wipe selection, acceptance, and quality management and is a core technical specification to maintain clean environments in high-value industries.

Conclusion:
By rigorously following the IEST-RP-CC004.4 standard, users can precisely select high-quality cleanroom wipes tailored to specific cleanroom scenarios, effectively reducing contamination risks, extending equipment lifetime, improving process yield, and enhancing product reliability, thereby supporting sustained growth in high-cleanliness industries.

Uster Swabs: Precision Cleaning Breakthrough

In industries with stringent cleanliness requirements such as semiconductor manufacturing, medical device maintenance, and optical instrument care, Uster cleanroom swabs have emerged as a benchmark tool for achieving efficient and contamination-free cleaning. Combining cutting-edge technology with multi-industry needs, these swabs offer a reliable and versatile solution for precision cleaning.

Core Technical Advantages: Precision, Efficiency, and Zero Contamination

  1. Premium Materials Tackling Complex Cleaning Challenges
    The swab tips are made from high-performance polyester fibers or polyurethane sponge. The polyester fiber tips offer excellent absorption, while the sponge tips provide strong liquid retention. Different materials suit various applications, allowing the swabs to reach narrow gaps and irregular surfaces. The cushioning effect also prevents mechanical damage to sensitive components like semiconductor wafers and optical lenses. For larger surface areas, wide-head swabs are available.

  2. Thermal Bonding Process Eliminates Secondary Contamination Risks
    Unlike traditional swabs that may leave adhesive residues or shed fibers, Uster swabs use advanced thermal bonding to seamlessly fix the tip materials to polypropylene shafts. This method ensures no adhesive contamination or fiber shedding occurs, and the strong bond withstands repeated wiping and solvent exposure, maintaining cleaning purity.

  3. ISO Class 5 Cleanroom Certification Meets Highest Standards
    Processed through proprietary cleanroom techniques, these swabs exhibit particle emissions and non-volatile residue (NVR) levels far below industry norms, fully complying with ISO Class 5 cleanroom requirements. They effectively maintain a contamination-free environment in chip production and medical instrument sterilization.

  4. Excellent Chemical Resistance for Extreme Cleaning Conditions
    The swab tips resist harsh solvents such as acetone, isopropanol (IPA), and methyl ethyl ketone (MEK), excelling at removing stubborn grease, solder flux residues, and biological contaminants while maintaining structural integrity to prevent tool degradation.

  5. No-Marking Cleaning Technology Protects Delicate Surfaces
    Optimized fiber density and elasticity enable controlled wiping pressure without scratching delicate surfaces like optical coatings and hard disk heads, significantly reducing the risk of scrapped high-precision equipment.

Versatile Applications Across Multiple Fields

  1. Optics and Semiconductor Industries
    Quickly removes lens watermarks, wafer particles, and photoresist residues, while preventing micro-scratches common with traditional swabs, safeguarding optical system imaging quality and chip yield.

  2. Industrial Manufacturing and Electronics Assembly
    Compatible with various industrial solvents, effectively cleans PCB solder points and injection-mold release agents, becoming a standard tool in cleanroom environments.

  3. Medical and Healthcare Sectors
    Meets medical device pre-sterilization cleaning standards, thoroughly removing adhesive residues and biological debris from surgical instruments, supporting GMP compliance for hospitals and IVD equipment manufacturers.

  4. High-End Equipment Maintenance
    An upgraded alternative to conventional cotton swabs, its low fiber shedding prevents secondary contamination during cleaning, widely used for aerospace precision components and laboratory analytical instruments.

Conclusion:
Driven by technological innovation, Uster cleanroom swabs upgrade cleaning standards by addressing traditional tools’ limitations in cleanliness, durability, and applicability. Through rigorous quality control and full lifecycle management, they provide trusted cleaning solutions for critical processes in semiconductors, biomedicine, medical equipment, and beyond, propelling precision manufacturing into a new era of cleanliness.

High-Level Cleanroom Wipes: Analysis & Guidance

In cleanroom management, selecting the appropriate cleanroom wiping materials is crucial for maintaining production environment quality and improving product yield. Cleanroom wipes (also called cleanroom nonwoven wipes) and cleanroom cloths are often confused, but there are significant differences in key performance and application scenarios between the two. So, can cleanroom wipes be used for wiping in high-level cleanrooms? This article analyzes the differences from the perspectives of edge-sealing technology, contamination control indicators, and cleanroom class compatibility, and provides professional recommendations.

1. Key Reasons Why Cleanroom Wipes Are Not Recommended for High-Level Cleanrooms

  • Edge Sealing Technology Differences and Potential Contamination

    • Cleanroom wipes generally use cold-cut edge sealing, resulting in relatively rough edges that tend to shed fibers during use, becoming uncontrolled particulate contamination sources in the cleanroom.

    • Cleanroom cloths adopt laser or ultrasonic edge sealing technology that creates a highly fused and smooth edge, greatly reducing or eliminating fiber shedding, meeting the stringent cleanliness requirements of high-level cleanrooms.

  • Differences in Contamination Control Indicators

    • Although some cleanroom wipes are manufactured in Class 10,000 environments (such as those by top brands), their production and post-processing generally lack the rigorous deep cleaning processes required for high-level cleanrooms. This means they may carry and release non-volatile residues (NVR), liquid particle counts (LPC), and ionic contaminants (such as sodium, potassium, chloride), which can directly affect precision manufacturing and electronic components.

    • Cleanroom cloths are specifically designed for high cleanliness, undergoing multiple ultrapure water washes and strict testing. Their NVR, LPC, and ion levels meet or exceed ISO Class 5 (Class 100) and higher standards. Some manufacturers offer up to Class 10 cleanroom cloths, widely used in advanced semiconductor manufacturing.

2. Cleanroom Class Compatibility

  • Cleanroom wipes are suitable for lower-level cleanrooms such as Class 10,000 and Class 100,000, as well as peripheral cleanroom areas (equipment exteriors, floors), where particle and chemical contamination control requirements are more lenient.

  • Cleanroom cloths are essential consumables for core areas in high-level cleanrooms (Class 100, Class 10, and above), suitable for direct contact with precision instruments, optical components, semiconductor wafers, and sterile pharmaceutical production equipment, ensuring that wiping does not introduce contamination risks.

3. Conclusion and Recommendations

  • Use cleanroom wipes only in lower-class cleanrooms or non-critical areas of high-level cleanrooms (such as equipment housing and floors) to leverage their cost-effectiveness.

  • Use cleanroom cloths exclusively in core process areas of high-level cleanrooms. Their superior edge sealing and stringent contamination control (low NVR, LPC, and ionic contamination) are fundamental to maintaining ultra-clean environments and protecting high-value products and processes.

  • Never substitute cleanroom wipes for cleanroom cloths in critical high-level cleanroom operations. When procuring, require suppliers to provide full cleanliness certification and contaminant test reports (NVR, LPC, Ions) to ensure product performance matches the cleanroom standards.

Properly distinguishing between cleanroom wipes and cloths by application scenario is the foundation for maintaining cleanroom operation efficiency and product quality. Selecting the right wiping materials minimizes contamination risks and supports the stable development of high-end manufacturing processes.

Cleanroom Wipes: Contamination Removal Analysis

In industries with stringent cleanliness requirements, cleanroom wipes serve as essential cleaning tools whose performance directly impacts production efficiency and product quality. This article analyzes the technical advantages of cleanroom wipes in contaminant removal from five core performance dimensions:

  1. Rapid Penetration and High Absorption Rate
    The fiber structure of cleanroom wipes determines their absorption capacity. Wipes made from 100% polyester fiber or microfiber (with fineness less than 1 denier) exhibit high porosity and capillary action, allowing quick penetration and absorption of liquids and contaminants. For example, microfiber diameter is only about 1/20 that of ordinary fibers, forming a dense network that significantly increases absorption speed (up to 7-10 times faster than conventional fabrics). This feature is critical in semiconductor manufacturing, where spills of solvents like isopropanol (IPA) can be absorbed within seconds, preventing contamination of sensitive components.

  2. Contaminant Trapping and Retention Mechanisms
    Cleanroom wipes achieve efficient contaminant capture through two main mechanisms:

  • Physical Trapping: The microfiber weave forms microscopic “traps” that capture particles as small as 0.1 μm, such as metal debris and dust. For instance, in optical lens cleaning, wipes lock abrasive residues in fiber gaps, avoiding secondary scratches.

  • Chemical Adsorption: Some wipes undergo hydrophilic treatment (e.g., 18MΩ ultra-pure CDI cleaning), adding polar groups on fiber surfaces that attract charged ionic contaminants like metal ions. This capability effectively removes photoresist residues during LCD panel manufacturing.

  1. Enhanced Surface Adhesion (Stickiness)
    The adsorption force of cleanroom wipes derives from:

  • Fiber Morphology: Microfibers have a larger specific surface area, increasing contact with contaminants by 30%-50% and enhancing physical adsorption.

  • Surface Modification Techniques: Plasma treatments or coatings (such as polyurethane) provide directional adhesion. For example, antimicrobial wipes used in healthcare contain silver ions on fiber surfaces that not only trap soils but also inhibit bacterial regrowth during surgical instrument cleaning.

  1. Ultrafine Fiber Fineness and Precision Wiping Compatibility
    Microfibers finer than 1 denier (e.g., 0.5 denier) offer the following benefits:

  • Low Particle Generation: Finer fibers generate fewer particles during friction, meeting ISO Class 5 cleanroom standards.

  • Surface Conformity: Thin fibers penetrate complex structures (like tiny PCB holes), enabling blind spot cleaning. In automotive electronics assembly, such wipes remove conductive dust in connector gaps, preventing short circuits.

  1. Stability of Contaminant Retention on Wipes
    Cleanroom wipes are designed to minimize contaminant shedding:

  • Edge Sealing: Laser-fused or ultrasonic welding eliminates fiber fraying and loose ends, reducing lint by over 90%. Aerospace wipes, for example, withstand high-frequency wiping without shedding.

  • Composite Structures: Some wipes feature dual-layer fibers (hydrophobic outer, hydrophilic inner), where contaminants are locked in the inner layer by capillary forces, preventing secondary contamination. This design meets FDA food safety standards for safely removing oily residues in food processing.

  1. Application Scenarios and Performance Validation

  • Electronics Manufacturing: Using microfiber wipes with IPA after wafer polishing reduces surface particle count from 10^3 particles/cm² to below 10 particles/cm².

  • Medical Sterilization: Sterile wipes reduce microbial residue by 99.9% on surgical instruments.

  • Optical Instruments: Tests by lens manufacturers show anti-static wipes limit light transmittance loss to less than 0.1%.

Conclusion:
The wiping performance of cleanroom wipes integrates material science, process technology, and application requirements. Innovations such as nanofiber technology and intelligent surface treatments will further enhance contaminant removal efficiency. Future developments may include pH-responsive adaptive cleaning materials and “smart wipes” with integrated sensors to monitor cleaning effectiveness in real time. These advances will elevate clean environment management in cutting-edge fields like semiconductors and biomedicine.

TOC Swab Sampling Errors: Impact & Key Factors

Recent studies have revealed that multiple variables in Total Organic Carbon (TOC) swab testing significantly increase sampling errors, which can severely affect cleaning validation results commonly used in the pharmaceutical industry. TOC swabs are a standard method for cleaning validation in pharmaceutical production, but their test results often exhibit high variability. Sampling error has been identified as a key cause of this variability.

A research team from Novo Nordisk and the Technical University of Denmark employed Monte Carlo simulation to quantitatively analyze sampling errors in real-world TOC swab sampling scenarios. They considered factors such as operator differences, residue concentration variation, stainless steel surface finish, sampling locations, and the estimated swab coverage area to build a comprehensive sampling error model. This simulation incorporated extensive laboratory experimental data and image analyses of blue dye-marked areas both in the lab and on old production tanks.

The researchers used the Limit of Detection (LOD) to determine recovery rates—the lowest analyte concentration detectable consistently at a 95% confidence level. Their findings showed that sampling errors cause significant fluctuations in TOC test results. When all variables were considered together, the LOD in laboratory settings was 2.4 times higher than that based solely on the TOC analytical method. Due to high heteroscedasticity (variance), the team was unable to define an LOD for the estimated sampling areas on production tanks.

Further analysis identified sampling area uncertainty as the dominant factor influencing sampling errors. The research team emphasized that precise control of sampling area is critical in practical applications to reduce errors and improve the accuracy and reproducibility of cleaning validation results.

In summary, this study provides important insights for optimizing TOC cleaning validation sampling methods in the pharmaceutical industry. It highlights the need for strict operational protocols and precise area control during sampling to ensure scientific rigor and regulatory compliance in cleaning validation.

Cleanroom Lighting: Key Color Temp & Lumens

In cleanroom design, the choice of ceiling components—especially the lighting system—plays a critical role in the overall effectiveness of the controlled environment. Proper lighting not only ensures visual comfort and operational accuracy for staff but also directly impacts contamination control and compliance with industry standards. This article explores the key parameters of “color temperature” and “lumens” in cleanroom lighting, helping organizations create a safe, efficient, and standards-compliant clean space.

1. The Meaning and Selection of Color Temperature

Color temperature describes the color tone of a light source and is measured in Kelvins (K), ranging from warm tones (around 2700K) to cool tones (over 6000K). For cleanrooms, a color temperature between 4000K and 5000K, offering neutral to slightly cool white light, is recommended. This range provides optimal visual clarity and contrast while reducing eye strain.

  • Why choose 4000K–5000K?
    This range balances visual comfort and color accuracy, making it ideal for environments like medical facilities and semiconductor manufacturing that require high precision. Cooler light also enhances focus and work efficiency.

  • Avoiding extremes of color temperature
    Too warm lighting can distort colors and affect precise judgment of products and instruments; too cool lighting can cause glare and discomfort.

2. The Importance of Lumens and How to Calculate Requirements

Lumens measure the total visible light emitted by a source and are a key indicator of brightness. Unlike watts, which measure energy consumption, lumens directly relate to visual experience.

  • Impact of lumens on cleanroom operations
    Adequate and evenly distributed lighting prevents shadows and visual fatigue, enabling operators to perform delicate and detailed tasks accurately. Lighting that is too dim or too bright can reduce efficiency and cause safety issues.

  • Calculating the required lumens

    • Generally, 300 to 500 lumens per square meter is recommended.

    • Highly precise work areas may require up to 1000 lumens per square meter for optimal visibility.

    • Consider ceiling height (higher ceilings require brighter lights) and task complexity (more complex tasks require higher brightness).

3. Environmental Factors and Cleanroom Class Requirements for Lighting

Cleanrooms have strict controls over airborne particles, temperature, humidity, and cleanliness levels. Lighting fixtures must meet these standards by:

  • Environmental adaptability
    Fixtures should have excellent sealing and chemical resistance to avoid becoming a source of particle contamination or being damaged by the environment.

  • Matching lighting to cleanroom class

    • ISO Class 1–3: Used in ultra-clean environments like semiconductor and biotech industries, requiring low heat and minimal particle emission lighting.

    • ISO Class 4–6: Common in pharmaceutical and medical device manufacturing, requiring fixtures that are easy to clean and resistant to chemical cleaners.

    • ISO Class 7–9: These spaces have looser particle restrictions but still require lighting that enhances visibility and reduces contamination risks.

4. Conclusion

Selecting the appropriate color temperature and lumens for cleanroom lighting improves visual comfort and supports contamination control and production accuracy. When designing and procuring lighting, companies should comprehensively consider cleanroom class, environmental conditions, and operational needs to develop an effective lighting plan that ensures safe and efficient cleanroom operation.

Microfiber Wipes: Benefits & Proper Techniques

In critical environments such as hospitals, electronic manufacturing plants (especially the semiconductor industry), and laboratories, thorough and complete cleaning is essential. Microfiber cleanroom wipes have become the preferred choice due to their outstanding cleaning performance. Proper usage procedures not only enhance cleaning efficiency but also effectively prevent cross-contamination and re-contamination. This article will introduce the advantages of microfiber cleanroom wipes and the correct wiping methods to help enterprises and users achieve effective cleanliness management.

1. Advantages of Microfiber Cleanroom Wipes

  • Superior Adsorption and Retention:
    Microfiber wipes are made from a blend of polyester and nylon fibers that are extremely fine and densely packed. This structure allows them to outperform traditional cloths, lint-free papers, or ordinary polyester wipes in capturing and retaining particles, oils, bacteria, and other contaminants.

  • Effective Surface Contaminant Removal:
    Microfiber can penetrate tiny crevices and effectively remove bacteria and dirt, making it ideal for cleaning electronic components, semiconductor wafers, and medical equipment surfaces.

  • Excellent Compatibility with Disinfectants:
    When used in combination with appropriate disinfectants, microfiber wipes can remove up to 99.99% of surface contaminants, significantly improving cleanliness and safety.

  • Balanced Cost and Performance:
    Although microfiber wipes cost more than traditional materials, their superior cleaning performance and contamination prevention make them the preferred choice for environments requiring high cleanliness standards.

2. Proper Wiping Techniques Using Microfiber Wipes

  • Strictly Follow Site Protocols:
    Wear suitable gloves and cleanroom garments to prevent personnel from becoming a contamination source.

  • Fold Wipes Properly:
    Fold the wipe twice into quarters, providing multiple clean surfaces and better contact with the wiping area.

  • Wiping Method:

    • Hold the folded edge towards your fingertips, gripping the unfolded edge with your thumb and forefinger to ensure you are using a clean wiping surface.

    • Use pre-moistened wipes or dampen the wipes with an appropriate disinfectant.

    • Wipe in one direction, overlapping each pass by 10% to 25% to avoid recontamination.

    • Start wiping from the cleanest area moving toward the dirtiest area, following a systematic pattern such as top-to-bottom or far-to-near, avoiding circular motions.

  • Record Keeping:
    Meticulously document which surfaces have been cleaned and which areas remain to be wiped to ensure no spots are missed.

  • Use Multiple Surfaces and Dispose Properly:
    Always use the cleanest side of the wipe first. If re-wiping is necessary, use a fresh clean area rather than the used portion. Dispose of used wipes according to site protocols to prevent secondary contamination.

3. Conclusion

Microfiber cleanroom wipes, with their exceptional cleaning capabilities, have become essential tools in critical clean environments. Proper wiping techniques and standardized usage are key to maintaining hygiene in cleanrooms, electronics manufacturing, and healthcare settings. Besides selecting suitable products, choosing reputable and reliable microfiber wipe manufacturers is equally important. For more details, see the article “How to Choose Microfiber Cleanroom Wipe Manufacturers and Suppliers.”

SMT Stencil Wipes: Essential for Electronics

In surface mount technology (SMT) production, the solder stencil is a core tool enabling precise solder paste printing. However, residues such as solder paste and red glue around the stencil apertures directly affect print quality, leading to defects like solder balls and bridging. SMT solder stencil cleaning wipes, as a key consumable for stencil cleaning, play a critical role in ensuring electronic product yield and reliability. This article analyzes their material characteristics, application scenarios, and industry development trends to highlight their core industrial value.

  1. Definition and Core Functions of SMT Solder Stencil Cleaning Wipes
    SMT solder stencil cleaning wipes are dust-free wiping materials designed specifically for SMT printers to remove excess solder paste, red glue, and other contaminants from the stencil underside and printed circuit boards (PCBs). Their main functions include:

  • High-efficiency cleaning: Physically adsorbing and chemically dissolving micron-level residues to prevent contamination of stencil apertures.

  • Defect prevention: Reducing defects like shorts and missing prints in the solder paste printing process to improve PCB yield.

  • Compatibility: Suitable for various SMT printers (e.g., DEK, MPM, EKRA) to meet diverse machine cleaning requirements.

Industry statistics indicate that about 50% of SMT final defects originate from the stencil printing process. Using high-quality wipes, such as those produced by Uster — a leading domestic manufacturer offering free samples and a full range of specifications compatible with common printer brands like DEK, MPM, Panasonic, and Sony — can significantly reduce such defects. Custom non-standard sizes are also supported.

  1. Material Characteristics and Performance Requirements
    SMT solder stencil wipes must meet strict standards for cleanliness, durability, and functionality. Typical material features include:

  • Dual-layer composite structure:

    • Wood pulp layer (textured side): Made from natural wood pulp fibers, soft and highly absorbent to conform to the stencil surface without scratching and capture dust.

    • Polyester layer (smooth side): Made of polyester fibers, wear-resistant with a “sieve effect” to reduce fiber shedding and prevent contamination of solder paste.

  • Spunlace technology: The wood pulp and polyester fibers are bonded via spunlace, creating a strong, low-lint nonwoven fabric.

  • Solvent compatibility: Wipes must be compatible with common cleaning solvents such as isopropanol (IPA) and alcohol to ensure rapid absorption and uniform distribution without chemical degradation or contamination.

  • Anti-static and low VOC design:

    • Anti-static treatment reduces dust attraction, crucial for high-precision electronics manufacturing.

    • Pre-saturated wipes reduce VOC emissions, protecting operator health and workplace safety.

  • Emerging material innovations:
    Future wipes may incorporate new materials such as polyester-wood pulp blends for faster absorption and durability, ultra-fine fibers for high-density circuits, or resin-bonded materials to enhance adhesion and cleaning effectiveness.

  1. Application Scenarios and Operation Guidelines
    SMT solder stencil wipes are widely used in:

  • Printer cleaning:

    • Manual/semi-automatic printers: Regular wiping of stencil undersides to prevent solder paste buildup.

    • Fully automatic printers: Integrated in automated cleaning systems for continuous production efficiency (e.g., DEK, MPM).

  • Abnormal handling:

    • Misprint repair: Quickly removing thick glue or partially cured epoxy with pre-saturated wipes.

    • Extreme contamination: Using high-absorbency foam wipes for stubborn residues on metal screens or thick-film prints.

  • Proper usage steps:

    • Differentiate wipe sides: The textured (wood pulp) side contacts the stencil, while the smooth (polyester) side contacts the cleaning solvent.

    • Spray solvent on the smooth side for even distribution.

    • Apply light pressure and wipe in a single direction to avoid re-contamination.

  1. Industry Trends and Future Directions

  • Environmental sustainability:

    • Reducing industrial waste and energy consumption.

    • Uster’s efforts in minimizing raw material waste through size optimization and deploying advanced production lines to maximize energy efficiency.

  • Smart customization:

    • Offering custom wipe widths and lengths tailored to printer models (e.g., Panasonic, Yamaha) and PCB sizes.

    • Developing intelligent monitoring systems to track wipe cleaning effectiveness and wear status in real-time.

  • Growth of high-end niche markets:

    • Formulating products dedicated to high-end and specialized SMT applications.

  1. Conclusion
    Though SMT solder stencil cleaning wipes may be considered a “hidden consumable,” their impact on product quality and manufacturing efficiency is undeniable. As SMT technology evolves toward higher density and speed, innovations in wipe materials and manufacturing processes will continue to drive industry advancement. Selecting wipes that meet specific production needs is key to reducing defects, promoting green manufacturing, and facilitating intelligent transformation.

7 Cleanroom Wiping Mistakes & Solutions

Using cleanroom wipes for wiping is a crucial part of maintaining cleanliness in cleanroom environments. However, many organizations fall into common mistakes that not only reduce cleaning effectiveness but can also cause contamination to spread. This article thoroughly analyzes the seven common mistakes when wiping cleanrooms with cleanroom wipes and offers practical solutions to help cleanroom managers improve cleaning efficiency and product quality.

  1. Neglecting the Necessity of Regular Wiping
    Cleanrooms and controlled environments require daily cleaning and maintenance using cleanroom wipes to prevent contaminant buildup. Contaminants generally fall into two categories: film-like residues and particulate contaminants, both of which can cause critical defects in microelectronics. Failure to clean regularly decreases cleanliness levels and leads to costly downtime and increased production costs. For example, in a Class 100 cleanroom, work areas should be wiped every shift, walls and corners thoroughly cleaned weekly, and other maintenance tasks performed as scheduled—skipping these increases particle accumulation.

  2. Using Unfolded, Flat Cleanroom Wipes
    Using cleanroom wipes unfolded wastes material and risks spreading contaminants rather than removing them. The correct method is to fold the wipe twice, forming a quarter size, which provides multiple clean surfaces and increases cleaning efficiency. Used wipes should be discarded according to protocols to avoid recontamination.

  3. Using One Wipe for an Entire Area
    A single cleanroom wipe, properly folded, provides approximately eight clean surfaces—each surface should be used only once. Using a contaminated surface further spreads contaminants. Wiping should be performed in one direction with 10%-25% overlap. After each use, flip the wipe to a clean surface. Prepare sufficient wipes to thoroughly clean the entire area.

  4. Wiping From Dirty/Wet Areas Toward Clean/Dry Areas
    Wiping in cleanrooms must follow a “clean to dirty” progression to avoid dragging contaminants into clean areas. Large spills or contamination should first be isolated and controlled using cleanroom-specific absorbent materials before wiping with cleanroom wipes, ensuring contaminants do not spread.

  5. Wiping in Circular Motions
    Wiping in circles disperses particles over a wider area, damaging the cleanroom environment. The correct approach is to apply firm, even pressure and wipe in straight, single-direction strokes with about 10% overlap, flipping the wipe to a clean surface after each pass.

  6. Using Wipes That Are Too Dry or Too Wet
    Dry wipes can capture some particles but achieve best results when slightly dampened. Overly wet wipes leave dirty residues, causing rework and wasted time. Depending on cleanroom grade and scale, choose either dry wipes used with a separate cleaning agent or pre-moistened wipes. When using dry wipes with cleaning agents, avoid direct contact between the bottle and wipe to minimize cross-contamination.

  7. Using Wipes Unsuitable for the Cleanroom Grade
    Different cleanroom grades require specific cleanroom wipe standards—for example, semiconductor industries typically require Class 100 or Class 10 wipes. Using inappropriate wipes compromises cleanliness and introduces risks. Select wipes that comply with industry standards and regulatory requirements tailored to your application.

Summary:
Proper use of cleanroom wipes is essential not only for cleaning efficiency but also for ensuring product quality and production safety. Avoiding these seven common mistakes and following standard operating procedures can effectively reduce contamination risk, extend cleanroom equipment life, and improve production stability and compliance.

Cleanroom Ops: Cleaning & ISO Compliance

  1. Cleanroom Cleaning, Gowning, and Maintenance Standards Guide

Proper cleanroom cleaning procedures and maintenance protocols are crucial and cost-effective measures to improve overall cleanroom cleanliness, consistency, and effective contamination control. This guide provides a framework for cleanroom management, covering cleaning standards, operational protocols, technical requirements, and related processes. It is applicable across general manufacturing, biomedical, and other diverse applications.

Since different cleanroom classifications may require varying consumables and operational workflows, this guide combines general best practices with specific application techniques to help formulate suitable gowning, wipedown, and particulate control plans tailored to actual needs. It aims to offer a comprehensive reference for consumable selection but does not replace professional advice for specific applications. For customized solutions, consulting qualified technical personnel or specialized suppliers is recommended.

  1. What is a Cleanroom?

A cleanroom is a controlled environment where the concentration of airborne particles is strictly regulated. It is designed and operated to minimize the introduction, generation, and retention of particles, while controlling other parameters such as temperature, humidity, and pressure as needed.

According to ISO 14644-1, clause 2.1.1:
A cleanroom is a controlled environment where products are packaged, manufactured, or assembled. This environment effectively eliminates submicron airborne contamination generated by personnel, processes, facilities, and equipment. The higher the cleanliness class, the lower the likelihood of particulate or microbial contamination affecting sterile or non-sterile products.

  1. Cleanroom Design and Construction

Cleanroom design and construction require stringent control of contamination sources, airflow velocity, pressure, temperature, and humidity. As a critical manufacturing resource, ensuring smooth production, assembly, storage, and inspection of products prior to delivery is vital.

Although most cleanrooms operate on similar principles, they differ significantly in control levels and particulate concentrations. The “dirtiest” cleanrooms may contain up to one million micron-sized particles per cubic meter of air, whereas the “cleanest” cleanrooms (e.g., ISO Class 3) may contain fewer than 1,000 particles per cubic meter.

The ISO classification system provides a unified industry standard for cleanliness and particle counts, enabling organizations to measure and test contamination levels against established benchmarks.

  1. Differences Between ISO 14644 and US Federal Standard FS 209E

The ISO 14644 standard replaced the earlier US Federal Cleanroom Standard FS 209E in 2001. Key differences include units and particle size classification methods:

  • FS 209E uses imperial units, counting particles per cubic foot of air.

  • ISO 14644 uses metric units, counting particles per cubic meter of air.

Additionally, ISO 14644 details smaller particle sizes starting from 0.1 microns, while FS 209E mainly focuses on 0.5-micron particle diameters.

It is important to note that these two standards are often confused, and some manufacturers’ technical datasheets may mistakenly reference both. For example, an FS 209E “Class 1” cleanroom’s particle limits roughly correspond to ISO Class 3. Unless explicitly stated as “ISO standard,” the default reference is usually FS 209E — which, although officially withdrawn by the US General Services Administration in 2001, remains widely used.

  1. Importance of Particle Counting

The impact of particles on production is not solely based on quantity, but rather whether particles of specific sizes cause issues for particular applications. The ISO cleanroom standard is more precise and versatile because it defines allowable particle counts across multiple size ranges from 0.1 to 5 microns.

With components becoming smaller and equipment more precise, the 0.5-micron standard is becoming outdated. Meanwhile, advances in particle counting technology enable unprecedented accuracy in detecting and differentiating airborne particles. For further information on cleanroom standards, international norms such as British Standards or EU GMP standards (e.g., Class A) may also be referenced.

  1. Cleanroom Gowning and Contamination Control

Proper gowning procedures form the first barrier to reduce personnel-introduced contamination. Protective garments such as cleanroom suits, shoe covers, and gloves must meet the required cleanliness levels, and gowning/de-gowning steps must be strictly followed to prevent particle shedding.

Surface wipedown uses dedicated lint-free wipes and approved disinfectants, with regular and as-needed cleaning to ensure equipment and surfaces remain particle- and microbe-free.

  1. Cleanroom Maintenance and Management Recommendations

  • Regularly evaluate cleaning effectiveness using scientific sampling and testing methods.

  • Establish training programs to enhance staff awareness and operational skills.

  • Optimize consumables procurement by selecting high-quality products that comply with ISO and GMP standards.

  • Employ automation and intelligent monitoring systems to improve management efficiency and responsiveness.

Conclusion:

Cleanroom cleaning, gowning, and maintenance are foundational to meeting industry standards and crucial to ensuring product quality and operational safety. A deep understanding of ISO standards and implementation details, combined with scientific workflows and efficient consumables management, will help enterprises continually improve cleanroom performance to meet increasingly stringent manufacturing and inspection demands.