1. Core Production Workflow
-
Material Selection:
-
Polyester/nylon microfibers (0.1-0.5μm diameter)
-
Medical-grade PP/PE packaging
-
-
Weaving Process:
-
Warp/weft knitting (Class 100-1000 cleanliness control)
-
-
Post-Processing:
-
Laser cutting (fiber shedding <0.01%)
-
Plasma anti-static treatment (surface resistance ≤10⁹Ω)
-
2. Critical Quality Control Points
✅ Cleanliness Testing:
-
Particle release (ISO 14644-1 Class 5)
-
Fiber residue (IEST-RP-CC004.3 method)
✅ Physical Properties: -
Tensile strength ≥50N/cm²
-
Liquid absorption <2 sec (AATCC 79)
3. Special Process Comparison
Process | Advantage | Application |
---|---|---|
Laser Cutting | Zero fraying | High-cleanliness wipes |
Ultrasonic Welding | No adhesive contamination | Medical-grade wipes |
Ion Beam Treatment | Permanent anti-static | Semiconductor wipes |
4. Production Environment Requirements
-
Air Cleanliness: Class 1000 cleanroom (Class 100 workstations)
-
Climate Control: 22±2℃/45±5% RH
-
Personnel Protocol: Full cleanroom suits + air showers
5. Industry-Specific Customization
-
Electronics:
-
Carbon fiber conductive layer (ESD protection)
-
-
Medical:
-
Gamma sterilization (25kGy dose)
-
-
Optics:
-
Silicone-free treatment (lens protection)
-